Rheolution Article | March 2022
How do hemostatic agents work?
by Dr. Dimitria Bonizol Camasao
Senior Application Specialist, Rheolution Inc.
The second topic of 2022 of our monthly publications was related to blood coagulation and hemostatic agents (HA). In our application note entitled “Measuring the efficacy of hemostatic agents using ElastoSens™ Bio”, two commercial hemostatic agents (CELOX™ and QUIKCLOT®) were tested with coagulating blood in the ElastoSens™ Bio. The curves of coagulation kinetics give information about the initiation clotting time and speed of clot formation which can be related to the efficacy of the HA. In the second publication, a scientific article reported a great candidate material for composing HA due to its ability to facilitate thrombin generation and consequently fibrin clot formation.
The basic mechanism of action of HA is to provide a barrier over the wound site to prevent excessive blood loss while forcing the agglomeration of cells and proteins in that area. The agglomeration of white and red cells, platelets, and clotting factors shortens clotting time (formation of an insoluble clot) favoring hemostasis and wound healing (illustrated in the image below).

Hemostatic agents can be subcategorized as absorbable agents, biological agents and synthetic agents. Absorbable agents are composed of natural biomaterials such as gelatin, oxidized cellulose, microfibrillar collagen and chitosan and can be found in the form of gauzes, powder, sponge, hydrogel, and films. This type of agent accelerates clotting time and is absorbed by the body within a few weeks. In addition, some of them provide an antimicrobial effect due to their low pH.
Biological agents include thrombin, fibrinogen and platelet agents. Thrombin are enzymes that play an essential role in the clotting cascade. It promotes the conversion of the protein fibrinogen (that circulates in the blood) into fibrin which helps to form an insoluble clot. This enzyme is purified from animal and human sources and can be injected pure at the wound site or mixed with fibrinogen and/or platelets with or without an absorbable agent. Fibrinogen and platelets are mostly human-derived.
Synthetic agents are polymers such as polyethylene glycol and cyanoacrylates that form stronger matrices used as sealants. They are normally liquid solutions that are injected at the wound site and rapidly form a polymer matrix that glues two surfaces together. They can be used as replacements for sutures or for filling holes of sutures and staples.
In the case of absorbable and synthetic agents, some side effects can include high swelling that may compress surrounding tissues, inflammation and immune reactions. In addition to these possible effects, the selection of the best HA depends on the type of bleeding, their interaction with the surrounding tissues, and the patient coagulation profile.
The number of HA has drastically increased in the last two decades and so the need for dedicated instrumentation to characterize the complex interaction of HA with blood. As shown in our application note, the ElastoSens™ Bio can provide valuable information about the overall blood absorption into the HA and the coagulation kinetics allowing the assessment of the HA efficacy. Dedicated instrumentation empower researchers to further improve HA for attending the large varied demand of this field such as in surgeries and non-surgical procedures, hemorragies, and trauma.
Reference
[1] Achneck, H. E., Sileshi, B., Jamiolkowski, R. M., Albala, D. M., Shapiro, M. L., & Lawson, J. H. (2010). A comprehensive review of topical hemostatic agents: efficacy and recommendations for use. Annals of surgery, 251(2), 217-228.
[2] Barkun, A. N., Moosavi, S., & Martel, M. (2013). Topical hemostatic agents: a systematic review with particular emphasis on endoscopic application in GI bleeding. Gastrointestinal endoscopy, 77(5), 692-700.
[3] Pogorielov, M. V., & Sikora, V. Z. (2015). Chitosan as a hemostatic agent: current state. European Journal of Medicine. Series B, (1), 24-33.
Related Posts
The human body has a natural mechanism to stop bleeding after an injury. Platelets migrate to the site of injury and start to form a soft blood clot. This activates other clotting factors in the bloodstream triggering a chain reaction to form a harder blood clot that will stay firmly in place.
The ElastoSens™ Bio was used to analyze the effects of hemostatic agents (HAs) on blood coagulation. The technology identified HAs that can alter clotting independently of the body's natural processes. These findings can optimize current HAs and aid in developing new ones.
Scientists from Dalhousie University, led by Dr. Mark Joseph Filiaggi, investigated the sodium polyphosphate (NaPP) polymer as a potential hemostatic agent. They tested six formulations of the biomaterial, with varying degrees of polymerization and types of divalent cations. The hemostatic potential of these formulations was evaluated using various blood clotting assays. The biomaterial was mixed with coagulation reagents and recalcified blood or plasma in a tube, which was then shaken to visually assess blood or plasma flow. The clotting time was noted as the time required to achieve no flow. Surgifoam®, a commercial hemostatic agent, was used as a control.
In a recent study published in the Critical Care Medicine Journal, researchers from Western Michigan University, the University of Texas, and healthcare-related offices across the United States investigated the relationship between COVID-19 and blood coagulation disorders. They found that analyzing the viscoelastic changes in coagulating blood can provide personalized information on a patient's coagulation state, offering valuable insights for treatment optimization. The study highlights the importance of a personalized patient-oriented approach due to the diverse clinical profiles observed in COVID-19 cases.
The viscoelastic properties of coagulating blood can be correlated with several diseases and genetic conditions that affect the natural blood coagulation process including bleeding disorders, hemophilia, rare factor deficiencies, von Willebrand disease and platelet function disorders. Therefore, the evaluation of blood clot properties can be valuable for the study, diagnosis and eventually treatment of these diseases.
Hemostatic agents (HA, e.g. powders, gauzes, adhesives and sealants) have been used for decades to control bleeding. The demand for these agents is growing due to two major trends in surgical practice: the expansion of minimally invasive surgery and complex reconstructive procedures that are more limited in their capacity to obtain hemostasis.